Vacuum diaphragm for turbocharger, adjusting
Turbocharger removed
Special tools, testers and auxiliary items required
- Dial gauge holder VW 387
- Hand vacuum pump VAS 6213
- Pressure regulator valve VAS 6342
- Turbocharger tester V.A.G 1397A
- Dial Gauge Set, 4-part VAS 6341
- Torque wrench V.A.G 1783
Special tools, testers and auxiliary items required
- Open End Spanner Insert AF 10 V.A.G 1783/1
Adjusting
- Tightening torques Part IV
- Remove hose - arrow - from vacuum diaphragm on turbocharger.
- Remove securing plate - 1 - over linkage on turbocharger.
- Loosen lock nut - 2 -.
- Pre-adjust bypass flap - 1 - via knurled nut - arrow - so flap can still just be turned by hand.
- Install lock nut hand tight.
Fig 7: Connecting Hand Vacuum Pump VAS 6213, Turbocharger Tester V.A.G 1397A To Connection II And Pressure Regulator Valve VAS 6342
- Connect hand vacuum pump VAS 6213 , turbocharger tester V.A.G 1397A to connection II and pressure regulator valve VAS 6342 as depicted in the illustration.
- Close Pressure Control Valve VAS 6342 on lever - 1 -.
- Adjust slide ring - 1 - on Hand Vacuum Pump VAS 6213 to - B - position for "Pressure".
- Switch on Turbocharger Tester V.A.G 1397A and adjust slide switch to position II.
Fig 9: Securing Dial Gauge VAS 6341/1 With 30 mm Extension VAS 6341/3 And Level Tester VAS 6341/4 On Universal Dial Gauge Holder VW 387
- Secure Dial Gauge Holder VW 387 on turbocharger - arrow -.
NOTE:
- The mm specifications apply to the value read out (includes 1 mm pre-load).
- Secure Dial Gauge 0-30 mm VAS 6341/1 with Dial Gauge Extension, 30 mm VAS 6341/3 and Flat Pickup VAS 6341/4 to Dial Gauge Holder VW 387.
- Set Dial Gauge 0-30 mm VAS 6341/1 to 1 mm pre-load with 0 bar on vacuum diaphragm.
- Rotate Dial Gauge 0-30 mm VAS 6341/1 display to 0.
- Check dial gauge for ease of movement.
- Operate Hand Vacuum Pump VAS 6213 until Turbocharger Tester V.A.G 1397A shows 350 +/- 5 mbar.
- Dial gauge must display between 4.1 mm and 4.33, otherwise, turn knurled nut until value is displayed.
- Hand tighten lock nut.
- Repeat measurement.
- Reduce pressure to 0 mbar via Pressure Control Valve VAS 6342.
- Set Dial Gauge 0-30 mm VAS 6341/1 to 0.
NOTE:
- The following measurements must be performed in one sequence. In the meantime, pressure must not dissipate to 0.
- Operate Hand Vacuum Pump VAS 6213 until Turbocharger Tester V.A.G 1397A shows 350 +/- 5 mbar.
- Read value on dial indicator VAS 6341/1 and note.
- Operate Hand Vacuum Pump VAS 6213 until Turbocharger Tester V.A.G 1397A displays 650 mbar to 700 mbar.
- Reduce pressure to 350 +/- 5 mbar via Pressure Control Valve VAS 6342.
- Read value on dial indicator VAS 6341/1 and note.
- Add value 1 and 2 and divide by 2.
- The result (mean value) must be 5 +/- 0.25 mm.
- If result (mean value) is not 5 +/- 0.25 mm, correct adjustment, tighten lock nut hand-tight and repeat measurement.
- If result (average) is 5 +/- 0.25 mm, tighten lock nut and secure with sealing wax. Sealing wax .
- Secure securing plate - 1 - over vacuum diaphragm linkage.