Battery, Testing with Midtronics Battery/Starting/Charging System Analyzer MCR340A
CAUTION:
Risk of injury from battery acid.
- Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures for lead-acid batteries for lead-acid batteries → Safety Precautions !
- Wear protective eyewear and clothing → 27 - Battery, Starter, Generator, Cruise control .
- If the magic eye has no color or is light yellow, the battery may not be tested or charged. Jump starting must not be used! There is a risk of explosion during testing, charging or jump starting. The battery must be replaced.
- DO NOT battery test batteries which are gassing. Otherwise there is a risk of explosion.
- Dispose of electrolyte (sulfuric acid/water mixture) properly! Waste electrolyte must only be disposed of in appropriate waste disposal sites. Refer to local regulations pertaining to electrolyte disposal.
- The following notes and procedures must be followed to ensure correct measurements.
Special tools, testers and auxiliary items required
- Midtronics Battery/Starting/Charging System Analyzer MCR340A (VAS tester illustrated here for reference only)
Procedure
CAUTION:
- Switch off all electrical consumers.
- Switch ignition off and remove ignition key.
- Refer to Midtronics Battery/Starting/Charging System Analyzer MCR340A Instruction Manual.
- On battery with charge indicator "Magic Eye" , check color display → Maintenance-Free Battery with Visual Indicator, Checking Color Display .
- Check no-load voltage → Battery No-Load Voltage - Vehicles without Energy Management Control Module, Checking .
- Connect tester cable clamps to battery terminal → MCR340A Instruction Manual. Tester leads must be securely fastened and make proper contact with battery posts.
- Select test mode "IN-VEHICLE" or "OUT-OF-VEHICLE" as appropriate → MCR340A Instruction Manual.
- Select battery type (AGM or conventional) → MCR340A Instruction Manual
- Set tester to "Warranty Test" → MCR340A Instruction Manual.
- Perform battery test by setting load current on tester according to battery (DIN) capacity → MCR340A Instruction Manual.
NOTE:
- Use print function of MCR340A in event test results are required for warranty claims.
Battery test results:
| Battery Tester Display / Printout | Required action |
| Good Battery | None |
| Good - Recharge | Charge battery where necessary |
| Use inCHARGE | Charge battery |
| Replace Battery | Replace battery. Electrical Equipment 27 Battery. |
| Bad Cell - Replace | Replace battery. Electrical Equipment 27 Battery. |
NOTE:
- If battery is replaced, follow disposal regulations → 27 - Battery, Starter, Generator, Cruise control .