Acc Setting Device: Vas 6190, Converting For Adjustment Procedure
Special Tools And Workshop Equipment Required
- ACC Adjustment Device:VAS 6190
Before performing adjustment, check in which mount the vertical slits on the :VAS 6190 are located. :VAS 6190 may have to be adapted before performing adjustment.
The :VAS 6190 must be adapted before adjustment procedure. If this is done during the adjustment procedure, the pre-calibration on the :VAS 6190 must be repeated.
-- For the adjustment procedure, the vertical slits in mounts -1- through -4- must be inserted so that laser beam is approximately centered vertically when it contacts the sensor lens.
-- The original nut at the top of the horizontal slits must be replaced with a standard nut -3-.
The original nut at the top of the horizontal slits must be replaced with a standard nut so that the mirror can be slide far enough to the center.
-- The mirror at the center -1- must be removed and re-installed all the way to the left -arrow- near the vertical slits -2-.
-- Then the mirror -1- must be slide on horizontal slits as far as stop on vertical slits -2-.