Home >> Audi >> 2008 >> Q7 4.2 >> Repair and Diagnosis >> External Pages >> Different car >> Section 30 (3.0L - Exhaust System & Emission Controls - Engine Code: CATA) >> 26 Exhaust System, Emission Controls >> Reducing Agent Metering System >> Reducing Agent Transfer Pump -V436-, REMOVING AND INSTALLING >> Removal

Reducing Agent Transfer Pump -V436-, REMOVING AND INSTALLING: Removal

WARNING: This page is about a different car, the 2011 Audi Q7, 2010 Audi Q7, and 2009 Audi Q7. However, it is still accessible from the selected car via links, so may be relevant.

Follow all safety precautions. Refer to WORKING ON REDUCING AGENT METERING SYSTEM, VEHICLES WITH SCR CATALYTIC CONVERTER .

Follow the guidelines for clean working conditions. Refer to FUEL SUPPLY, INJECTION SYSTEM AND CHARGING SYSTEM CLEAN WORKING CONDITIONS .

WARNING:

Danger due to reducing agent leaking out.

-- Remove the reducing agent passive tank (lower). Refer to REDUCING AGENT PASSIVE TANK, REMOVING AND INSTALLING .

NOTE:

Place a clean cloth under the separating location to catch any reducing agent that may leak out.

Seal off all open lines and connections with clean plugs.

Fig 1: Reducing Agent Transfer Pump And Rubber Bracket -2-
GWWA20-10664Courtesy of AUDI OF AMERICA, LLC
WARNING:

The reducing agent can cause skin irritation.

  • Avoid contact with skin and eyes! Always wear protective gloves and safety glasses.
  • If reducing agent should get on your skin, wash it off immediately with soap and water.
  • If reducing agent gets in your eye, rinse the eye for several minutes with water.
  • Never inhale or swallow the reducing agent!
  • Should you swallow any reducing agent, rinse your mouth, drink plenty of water and contact a doctor immediately.

-- Remove the transfer line -1- by pressing the release button.

-- Clamp off the hose -5- with the Hose Clamps - Up To 25mm 3094.

-- Carefully remove the hose from the connection on the Reducing Agent Transfer Pump -V436-.

-- Disconnect the connector -3-.

-- Remove the screw -4- and remove the Reducing Agent Transfer Pump -V436- and rubber bracket -2-.