LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2008 >> A5 Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> AIR CONDITIONING R1234yf (REFRIGERANT CIRCUIT) (COUPE) >> 87 Air Conditioning >> Refrigerant Circuit >> System Overview - Refrigerant Circuit >> System Overview - Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module)

System Overview - Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module)

NOTE:

The arrows indicate the refrigerant flow direction.

The following illustration shows a refrigerant circuit with an expansion valve and a second evaporator for cooling the battery and an inner heat exchanger as an example.

The Layout Of The Refrigerant Circuit Is Vehicle-Specific. Refer To REFRIGERANT CIRCUIT - 1 , REFRIGERANT CIRCUIT - 2 , REFRIGERANT CIRCUIT 1234yf - 2 , REFRIGERANT CIRCUIT GENERAL INFORMATION R134a , REFRIGERANT CIRCUIT R134a .

HD  = High Pressure Side

ND  = Low Pressure Side

Fig 1: Refrigerant Circuit With Electrically-Driven A/C Compressor (With Or Without Battery Cooling Module) Component Locations
GWWA87-11246Courtesy of AUDI OF AMERICA, LLC
  1. Electrically-Driven A/C Compressor
  2. Pressure Relief Valve
  3. Condenser
    • With receiver/dryer and dryer cartridge.
  4. Receiver/Dryer
    • Is a component of the condenser
  5. Refrigerant Pressure Sensor
  6. Service Connection - High Pressure Side
    • With closure cap.
  7. Refrigerant Line with Inner Heat Exchanger
  8. Refrigerant Shut-Off Valve
    • Different names. Refer to the appropiate service information HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 1 -N516-, REMOVING AND INSTALLING and EXPANSION VALVE WITH HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 2 -N517 .
    • Only on vehicles with a battery cooling module for the Hybrid Battery Unit -AX1-.
      NOTE:

      The Refrigerant Shut-Off Valve is for example activated, if the battery needs to be cooled and the vehicle interior is not already being cooled (open without activation).

  9. Expansion Valve
    • On the heater and A/C unit evaporator
  10. Front Evaporator
    • Heater and A/C unit evaporator
  11. Expansion Valve with Shut-Off Valve
    • Different names. Refer to the appropriate service information, HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 1 -N516-, REMOVING AND INSTALLING and EXPANSION VALVE WITH HYBRID BATTERY REFRIGERANT SHUT-OFF VALVE 2 -N517 .
    • On the evaporator in the battery cooling module
    • Only on vehicles with a battery cooling module for the Hybrid Battery Unit -AX1-.
      NOTE:

      The Expansion Valve with Shut-Off Valve is activated when it is necessary to cool the battery (closed without activation).

  12. Evaporator
    • Evaporator in the battery cooling module
    • Only on vehicles with a battery cooling module for the Hybrid Battery Unit -AX1-.
  13. Service Connection - Low Pressure Side
    • With closure cap