Home >> Audi >> 2008 >> A5 Standard >> Repair and Diagnosis >> Accessories & Equipment >> Cruise Control Systems >> Wheels, Tires, Wheel Alignment (Suspension, Wheels, Steering) (General Information) (Coupe) >> 44 Wheels, Tires, Wheel Alignment >> Diagnosis And Testing >> Adjustment Procedure Using Acc Setting Device:Vas 6190 >> Calibration Procedure Without A Previous Axle Alignment

Calibration Procedure Without A Previous Axle Alignment

-- Connect Battery Charger. Refer To BATTERY, CHARGING WITH BATTERY CHARGER :VAS5900 .

-- Select The ACC Calibration Button On The Alignment Computer.

-- Mount The Quick Clamps To The Rear Wheels.

-- Mount The Measurement Sensor To The Rear Wheels.

-- Perform A Wheel Run-Out Compensation And The Rear Wheels.

NOTE:

The : VAS 6190  Must Not Be Moved On The Calibration Beam.