Carbon-Ceramic Brake Wear Tester: Vas6813, Checking
"Before" The Measurement The :VAS6813 Must Be Checked Using The Supplied Measurement Plate.
Measurement Plate:
-- Place The Measuring Device In Both Openings Of The Measurement Plate, -Arrows- So That The Laser Beam Points Under The Mark With The Attached Reference Value.
-- Switch On The Measuring Device.
The Value Displayed On The Display Must Correspond To The Reference Value Attached To The Measurement Plate.
NOTE:
If The Difference To The Reference Value Is More Than ± 2.0 Units The Measuring Device Must Be Recalibrated By A Specialist Company.
For More Information Refer To The Supplied Owner's Manual.