LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2007 >> S6 >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Electrical Equipment - General Information >> 27 - Battery, Starter, Generator, Cruise control >> Battery, Charging >> Battery, Quick Charging >> Battery, Quick Charging

Battery, Quick Charging

CAUTION: Risk of injury from battery acid.
  • Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures for lead-acid batteries for lead-acid batteries → Safety Precautions  !
  • Wear protective eyewear and clothing.
  • On non-maintenance-free batteries, the sealing plugs must be installed tightly.
  • Provide sufficient ventilation.
  • If the magic eye has no color or is light yellow, the battery may not be tested or charged. Jump starting must not be used! There is a risk of explosion during testing, charging or jump starting. The battery must be replaced.
  • DO NOT battery test batteries which are gassing. Otherwise there is a risk of explosion.
  • Rapid-charging batteries → Battery, Quick Charging .
  • Dispose of electrolyte (sulfuric acid/water mixture) properly! Waste electrolyte must only be disposed of in appropriate waste disposal sites. Refer to local regulations pertaining to electrolyte disposal.
  • The following notes and procedures must be followed to ensure correct charging.

Prerequisite

Procedure 

CAUTION: Risk of damaging the battery and vehicle electronic components.
  • DO NOT quick charge AGM batteries!
  • Batteries in vehicles with Energy Management Control Module J644 must not be quick charged.
  • Do not quick charge severely discharged batteries.
  • Quick charging of batteries should only be performed in exceptional circumstances (e.g. boost starting) as Quick charging may cause damage.
  • Battery must not be connected to vehicle electrical system when performing Quick charging. Disconnect the positive and negative cables from battery terminals. Refer to 27 - STARTER, GENERATOR, CRUISE CONTROL .
  • Do not exceed maximum charging voltage of 14.8 Volts.
NOTE:
  • If battery is replaced, follow disposal regulations.