Checking internal resistance
- Connect hand multimeter V.A.G 1526 A or V.A.G 1526 B for resistance measurement as follows.
| Leak detection pump (LDP) Terminal | Specified value |
|---|---|
| - 1 - + - 3 - | 640 to 720 Ω |
| - 2 - + - 3 - | 15 to 17 Ω |
If specifications are not obtained:
- Replace Leak Detection Pump (LDP) V144 → Leak Detection Pump (LDP) V144 , removing and installing .
If specified values are achieved:
- Check voltage supply of leak detection pump Checking voltage supply .