SID: Distance remaining until next Inspection Service (adaptation after replacing instrument cluster)
This function is used after replacing the instrument cluster to enter the distance remaining before the next Inspection Service is due.
| Rapid data transfer HELP Select function XX |
Indicated on display:
- Press buttons -1- and -0- and confirm input with Q button.
| Adaptation Enter channel number XX |
Indicated on display:
- Press buttons -4- and -0- to access "channel 40".
- Press -Q- button to confirm input
| Channel 40 Adaptation 0 → < - 1 3- > |
Indicated on display: for new instrument cluster:
The distance remaining before the next Inspection Service is due must be transferred from the old instrument cluster (e.g. 5000 km = adaptation value 50).
NOTE:
- The distance can only be entered in steps of 100 km (62 mi.). Accordingly, the readout on the display will also be in steps of 100 km (62 mi.).
- The entered value is counted upward from 0 to 15000.
- Input values when replacing instrument cluster. Refer to Replacement instrument cluster input values, adapting .
- The number can only be entered directly via the button pad on the scan tool.
- If an incorrect value is entered the adaptation function will be terminated and must be re-started.
- Press → button.
| Channel 40 Adaptation 0 Enter adaptation value XXXXX |
Indicated on display:
- Enter required value (noted from old unit) via button pad on scan tool, filling in the initial spaces with "0."
Example:
Distance remaining: 5000 km
Input value: 00050
| Channel 40 Adaptation 0 Q Enter adaptation value 00050 |
Indicated on display (example only):
- Press -Q- button to confirm input
| Channel 40 Adaptation 50 Q < - 1 3- > |
Indicated on display:
- Press -Q- button to confirm input
| Channel 40 Adaptation 50 Q Store changed value? |
Indicated on display:
- Press -Q- button to confirm input
| Channel 40 Adaptation 50 → Changed value is stored |
Indicated on display:
- Press → button to terminate adaptation of service interval display.