Center Defroster Outlet, Removing and Installing
Special tools, testers and auxiliary items required
- Trim removal wedge 3409
- Feeler gauge
Removing
- Unclip cover cap - 1 - using a feeler gauge 0.35 mm - 2 - out of center defroster vent - arrow -.
- Pry out Sunlight Photo Sensor G107 - item 3 - and disconnect harness connector.
- Remove bolt - 1 -.
- As depicted in the illustration, pry center defroster vent - 2 - out of instrument panel using trim removal wedge 3409.
Installing
Installation is reverse of removal.
Tightening torque:
Center defroster vent to instrument panel: 2 Nm