Instrument Panel Vent, Removing and Installing
Special tools, testers and auxiliary items required
- Hook 3438
Removing
- Turn knurled wheel - 3 - or air outlet vent completely upward.
- Insert one watchmakers screwdriver each - 1 - into air vent retaining clamps above the lower ventilation fin - 2 -.
- Pull air vent alternating on left and right side out of the installation opening, watchmakers screwdrivers must remain inserted while doing this.
NOTE:
- Pull air vent out of installation opening using Hook 3438 if necessary.
- Disconnect electrical harness connector at air vent.
Installing
Installation is reverse of removal.