Read Measuring Value Block (function 08): Notes
Use this function to observe various instrument cluster inputs and stored data.
The measuring value block is divided into 4 display groups, each containing 4 display fields.
| Rapid data transfer HELP Select function XX |
Indicated on display:
- Press buttons -0- and -8- to select "Read Measuring Value Block"function 08.
| Rapid data transfer Q 08 Read Measuring Value Block |
Indicated on display:
- Press -Q- button to confirm input
| Read Measuring Value Block HELP Enter display group number XXX |
Indicated on display:
- Enter desired Display Group number from table. Refer to Read Measuring Value Block (function 08)
- Press -Q- button to confirm input.
The Read Measuring Value block selected will appear in standard format.
Interpreting displayed information. Refer to Read Measuring Value Block (function 08)
NOTE:
- The display on the scan tool will always show the actual values obtained from the senders and sensors. The values which appear on the instrument cluster are filtered and may not be the same.
- If the actual coolant temperature is between about 80 ° C and 100 ° C, the instrument cluster will always show 90 ° C.
- The display groups shown here are the only ones which can be called up for the instrument cluster.
Display groups, summary
| Display Group No. | Indicated on display: | |
| 001 | 1 = road speed 2 = engine speed (RPM) 3 = oil pressure switch 2 ( < min) 4 = time (h) |
|
| 002 | 1 = odometer reading 2 = fuel gauge 3 = fuel gauge sender (Ohm) 4 = ambient temperature |
|
| 003 | 1 = coolant temperature | |
| 050 | 1 = odometer reading 2 = engine speed (RPM) 3 = oil temperature 4 = coolant temperature |
|