Adaptation channel 03-Adaptation of fuel consumption display
Display on VAS 5051:
Fig 1: VAS 5051 Tester Display - Adaptation Channel 03, Adaptation Of Fuel Consumption Display (1 Of 3)
- Enter channel number Max. input value = 99
- Select function "03" in button field -2- for "Adaptation channel 03" and press Q button to confirm input.
Display on VAS 5051:
Fig 2: VAS 5051 Tester Display - Adaptation Channel 03, Adaptation Of Fuel Consumption Display (2 Of 3)
- Channel 3 read and test
- Consumption-display
- Keypad - only direct input via the keypad is possible
- The sliding bar is positioned on the current adaptation value 100
NOTE:
- Value entered must be between 85% and 115%.
- Value must be entered in steps of 5%.
- If the value "100" was changed due to a customer complaint, the changed value must be transferred when replacing instrument cluster.
- Change adaptation value via direct input. See B - Change adaptation value via direct input: .
- Enter 5-digit adaptation value. Fill empty spaces with "0".
Example:
Desired input value: 90%
Keypad input: 00090
NOTE:
The "Save" button does not appear if an incorrect value was entered!
Display on VAS 5051 after performed adaptation:
Fig 3: VAS 5051 Tester Display - Adaptation Channel 03, Adaptation Of Fuel Consumption Display (3 Of 3)
- Channel 3 Value 90 stored
- End function "10 - Adaptation" by pressing <= button.