Work procedure
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2004 Audi A6, 2003 Audi S6, 2003 Audi A6, 2002 Audi S6, and 2002 Audi A6. However, it is still accessible from the selected car via links, so may be relevant.
- Connect diagnostic tester. See CONNECT DIAGNOSTIC TESTER .
- Start engine and let run at idle.
- In diagnostic function "33 - OBD", select "Mode 5: Check output of oxygen sensor signals".
- Via the following table, select the desired output of oxygen sensor signals according to Test ID (Test Identification), e.g. "01: Rich to lean sensor barrier voltage".
- Check specified values at idle.
NOTE:
- Bank 1 = cylinder bank 1 in direction of travel, right; Bank 2 = cylinder bank 2 in direction of travel, left.
- When selecting the diagnostic mode, the entry is always performed in "Bank 1 sensor 1".
- If either the VAG1551/1552 Scan Tool (ST) or VAS5051/5052 Vehicle Diagnostic, Testing and Information System is used for checking the output of oxygen sensor signals, the respective oxygen sensor can be selected by pressing button 1, 2, 5 and 6:
- Button 1 = Bank 1 sensor 1,
- Button 2 = Bank 1 sensor 2,
- Button 5 = Bank 2 sensor 1,
- Button 6 = Bank 2 sensor 2.
TEST-ID EVALUATION (MODE 5)
- End diagnosis and switch ignition off.