Maximum time interval
This function is used to set a fixed maximum time in days in the instrument cluster for the SRI.
Indicated on display
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
- Press -Q- button to confirm input.
Indicated on display:
- Press buttons 4- and -4-.
- Press -Q- button to confirm input.
Indicated on display (example only): Factory adjusted value for the time in days until next service is indicated (here for example 365 represents 365 days).
NOTE:
- The currently valid specifications can be found in the "Maintenance" book.
- Input of current specified value is only possible in units of one day, indication in display also changes in units of one day.
- When replacing instrument cluster, this value is already adjusted.
- It is only possible to input values via direct input using the keypad of the scan tool.
- If incorrect value is input, the "Adaptation" function is terminated and must be re-initiated.
- Press --> button.
Indicated on display (example only):
- Input specified value via keypad, fill initial positions with "0."
Specification: 365 days
Input value: 00365
Indicated on display (example only):
- Press -Q- button to confirm input.
Indicated on display (example only):
- Press -Q- button to confirm input.
Indicated on display (example only):
- Press -Q- button to confirm input.
Indicated on display (example only):
- End adaptation of maximum time interval by pressing the --> button.