LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2003 >> A6 Base >> Repair and Diagnosis >> Electrical >> Gauges >> On Board Diagnostic (OBD) - 2001 And Up >> Instrument cluster, On Board Diagnostic (OBD) >> Adaptation (function 10) >> Adaptation channel 41 - time since service

Adaptation channel 41 - time since service

This function is used to input the time in days since the last service.

Display on VAS 5051:

Fig 1: Display On VAS 5051 - Adaptation Channel 41, Time Since Service (1 Of 3)
G02720580Courtesy of AUDI OF AMERICA, INC.

Display on VAS 5051:

Fig 2: Display On VAS 5051 - Adaptation Channel 41, Time Since Service (2 Of 3)
G02720581Courtesy of AUDI OF AMERICA, INC.
  1. Channel 41

    read and test

  2. Actual value In spec. in 1 Days
  3. Keypad - only direct input via the keypad is possible
  4. The sliding bar is positioned on the current adaptation value, e.g. 110 Time in days since last service is displayed (here for example 110 represents 110 days)
NOTE:
  • Input of the current specified value is only possible in units of one day, indication in display also changes by units of one day.
  • When replacing instrument cluster, observe. See Input values for replacing instrument cluster  .

Example:

Desired input value: for example 200 days

Keypad input: 00200

Display on VAS 5051 after performed adaptation:

Fig 3: Display On VAS 5051 - Adaptation Channel 41, Time Since Service (3 Of 3)
G02720582Courtesy of AUDI OF AMERICA, INC.
  1. Channel 41

Value 200 stored