LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2003 >> A6 Base >> Repair and Diagnosis >> Electrical >> Gauges >> On Board Diagnostic (OBD) - 2001 And Up >> Instrument cluster, On Board Diagnostic (OBD) >> Adaptation (function 10) >> Adaptation channel 02-Resetting SRI after service

Adaptation channel 02-Resetting SRI after service

NOTE:
  • The Service Reminder Indicator (SRI) is used to remind the driver when a service is necessary. Indication is in center display.
  • Service reminder appears 1 month or 1200 miles before service limit is reached. Example for display: After a total driving distance of 7000 miles, "SERVICE IN 1000 miles" is indicated.
  • When a service event arrives, the text information appears in the center display for 5 seconds when ignition is switched on. It is shown after the note for automatic transmission and a target input for navigation (if applicable). Display: "SERVICE!".
  • The currently valid specifications can be found in the "Maintenance" book.

    See MAINTENANCE .

  • Data version of instrument cluster. See Figure .
  • Channels 40, 41 and 45 are automatically set to "0".

Display on VAS 5051:

Fig 1: VAS 5051 Tester Display - Adaptation Channel 02, Resetting SRI After Service (1 Of 3)
G02720549Courtesy of AUDI OF AMERICA, INC.
  1. Enter channel number Max. input value = 99

Display on VAS 5051:

Fig 2: VAS 5051 Tester Display - Adaptation Channel 02, Resetting SRI After Service (2 Of 3)
G02720550Courtesy of AUDI OF AMERICA, INC.
  1. 1 - Channel 2 read and test
  2. 2 - No indication
  3. 5 - Sliding bar is positioned on "1" Service is active, i.e. "SERVICE!" is displayed in the instrument cluster.

The service event is reset using the following adaptation value:

ADAPTATION VALUE

Adaptation value Service event
00000 Reset

Display on VAS 5051 after performed adaptation:

Fig 3: VAS 5051 Tester Display - Adaptation Channel 02, Resetting SRI After Service (3 Of 3)
G02720551Courtesy of AUDI OF AMERICA, INC.
  1. Channel 2 Value 0 stored
NOTE: 0 means service has been reset, i.e. "SERVICE IN 1000 MI" is displayed in instrument cluster after call-up.