Operation 5: Checking oxygen sensor heater: Notes
WARNING: This page is about a different car, the 2003 Audi S6 and 2002 Audi S6. However, it is still accessible from the selected car via links, so may be relevant.
Initiate basic setting Q
- Enter "041" for "display group number 041" and confirm entry with Q key.
Display readout
- Check specified values in display zones 1 and 3:
NOTE:
By increasing the engine speed the achieving of the specified values can be accelerated.
DISPLAY GROUP 41: OXYGEN SENSOR HEATING, BANK 1 AT IDLING SPEED
| Display zones | ||||
|---|---|---|---|---|
| 1 | 2 | 3 | 4 | |
| Display group 41: Oxygen sensor heating, bank 1 at idling speed | ||||
| Display | xxx kOhm | Htg. bC. ON | xxx kOhm | Htg. aC. ON |
| Display | Bank1 - sensor 1 | Status of heating | Bank1 - sensor 2 | Status of heating |
| Range | Htg. bC. ON Htg. bC. OFF |
Htg. aC. ON Htg. aC. OFF | ||
| Specified value | Smaller than 2 kOhm | Htg. bC. ON | Smaller than 2 kOhm | Htg. aC. ON |
| Note: | See IMPORTANT NOTES FOR DISPLAY GROUPS 41 AND 42: DISPLAY ZONES 1 AND 3: . | See IMPORTANT NOTES FOR DISPLAY GROUPS 41 AND 42: DISPLAY ZONES 1 AND 3: . | ||
- Press C key.
- Press keys 0, 4 and 2 for "display group number 42" and confirm entry with Q key.
DISPLAY GROUP 42: OXYGEN SENSOR HEATING, BANK 2 AT IDLING SPEED
| Display zones | ||||
|---|---|---|---|---|
| 1 | 2 | 3 | 4 | |
| Display group 42: Oxygen sensor heating, bank 2 at idling speed | ||||
| Display | xxx kOhm | Htg. bC. ON | xxx kOhm | Htg. aC. ON |
| Display | Bank 2, sensor 1 | Status of heating | Bank 2, sensor 2 | Status of heating |
| Range | Htg. bC. ON Htg. bC. OFF |
Htg. aC. ON Htg. aC. OFF |
||
| Specified value | Smaller than 2 kOhm | Htg. bC. ON | Smaller than 2 kOhm | Htg. aC. ON |
| Note: | See IMPORTANT NOTES FOR DISPLAY GROUPS 41 AND 42: DISPLAY ZONES 1 AND 3: . | See IMPORTANT NOTES FOR DISPLAY GROUPS 41 AND 42: DISPLAY ZONES 1 AND 3: . | ||