Adaptation (function 10): Notes
Individual functions are called up by entering the appropriate adaptation channel numbers (See adaptation table. See Adaptation Table ).
NOTE:
- Using measuring value blocks 010, 011, 012 and 015, the values that need to be transferred to the new instrument cluster can be read out before replacement.
- Adaptation channels 42, 43, 44 and 45 (Measuring value blocks 013 see Measuring value block 013 , 014 see Measuring value block 014 and 015 see Measuring value block 015 ) must be adapted when the instrument cluster is replaced.
- Adaptation channels 60, 61, and 62 are only needed when the instrument cluster communicates with the corresponding BUS system.
- Measuring value blocks 125 and 126. See Measuring value block 125 and Measuring value block 126 . Indicate the participants in the powertrain CAN-bus.
- Measuring value block 130. See Measuring value block 130 . Indicates the participants in the comfort system CAN-bus.
- Measuring value block 140. See Measuring value block 140 . Indicates the participants in the information CAN-bus.