Initiating "Adaptation" function 10
- Initiate output Diagnostic Test Mode of instrument cluster. See INSTRUMENT CLUSTER ON BOARD DIAGNOSTIC (OBD), INITIATING .
Display on VAS 5051:
- In selection -1-, select the diagnostic function "10 -Adaptation".
Display on VAS 5051:
- Enter channel number Max. input value = 99
- Enter desired adaptation channel in button field -2-. See ADAPTATION TABLE .
- Press -Q- button to confirm input.
Example for adaptation channel 01-volume of rear warning buzzer:
Display on VAS 5051:
- Enter channel number Max. input value = 99
- Select function "01" in button field -2- for "Adaptation channel 01" and press Q button to confirm input.
Display on VAS 5051:
- 1 - Channel 2 read and test
- 2 - Steering wheel X X WSC X
- 5 - The sliding bar is positioned on the current adaptation value, e.g. 5
A - Changing adaptation value using sliding bar:
Display on VAS 5051:
Fig 5: Display On VAS 5051 - Changing Adaptation Value Using Sliding Bar, Parking Assistance (1 Of 3)
- Move sliding bar -5- into desired direction or press on the surface beside the sliding bar, to move it in the desired direction.
- Press "Save" button -4-.
Display on VAS 5051:
Fig 6: Display On VAS 5051 - Changing Adaptation Value Using Sliding Bar, Parking Assistance (2 Of 3)
- 1 - Channel 1 save
- 2 - Steering wheel 0 4 WSC 0
- 4 - original value 1 new value 4
- Confirm new adaptation value by pressing the "take over" button -3-.
Display on VAS 5051:
Fig 7: Display On VAS 5051 - Changing Adaptation Value Using Sliding Bar, Parking Assistance (3 Of 3)
- Channel 1 Value 4 stored
- End function "10 - Adaptation" by pressing <-- button.
B - Change adaptation value via direct input:
Display on VAS 5051:
- Press "Keypad" button -3-.
Display on VAS 5051:
- Enter adaptation value Input value: 0 to 65535
- Enter 5-digit adaptation value in button field -2-. Insert zeros in front.
Example:
Desired input value: 4
Keypad input: 00004
- Press -Q- button to confirm input.
Display on VAS 5051:
- 1 - Channel 1 save
- 2 - Steering wheel 0 4 WSC 0
- 4 - original value 1 new value 4
- Confirm new adaptation value by pressing the "take over" button -3-.
Display on VAS 5051:
- Channel 1 Value 4 stored