Home >> Audi >> 2002 >> allroad Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 39 (On Board Diagnostic (OBD) - 4.2L V8 5V - BCY) >> On Board Diagnostic (OBD) >> Readiness code, reading >> Readiness code, generating >> Step 11: Diagnosis of oxygen sensor aging after catalytic converter >> Condition

Step 11: Diagnosis of oxygen sensor aging after catalytic converter: Condition

WARNING: This page is about a different car, the 2003 Audi RS 6. However, it is still accessible from the selected car via links, so may be relevant.

Indicated on VAS 5051:

Fig 1: Function Display VAS 5051 - Generating Readiness Code, Diagnosis Of Oxygen Sensor Aging After Catalytic Converter (1 Of 4)
G03613380Courtesy of AUDI OF AMERICA, INC.
  1. - Enter display group

Indicated on VAS 5051:

Fig 2: Function Display VAS 5051 - Generating Readiness Code, Diagnosis Of Oxygen Sensor Aging After Catalytic Converter (2 Of 4)
G03613381Courtesy of AUDI OF AMERICA, INC.
DISPLAY GROUP 043: OXYGEN SENSOR AGING AFTER CATALYTIC CONVERTER (BANK 1)

  Display zones
1 2 3 4
Display group 043: Oxygen sensor aging after catalytic converter (bank 1) 
Display  xxx rpm xxx °C x.xxx V Test ON 
Significance  Engine speed Exhaust gas temperature Voltage of oxygen sensor downstream of catalytic converter, bank 1 Diagnosis status
Operating range  min.: 550 rpm
max.: 6700 rpm
70...850 °C 0.0...1.0 V Test OFF
Test ON
B1-S2 OK
B1-S2 not OK
Specification  700...790 rpm  200...300 °C 0.000...1.000 V B1-S2 OK
Note        If "B1-S2 not OK" is displayed: Interrogate fault memory, see  FAULT MEMORY, INTERROGATING AND ERASING  

If specification "B1 -S2 OK" is obtained in display zone 4:



Indicated on VAS 5051:

Fig 1: Function Display VAS 5051 - Generating Readiness Code, Diagnosis Of Oxygen Sensor Aging After Catalytic Converter (3 Of 4)
G03613382Courtesy of AUDI OF AMERICA, INC.
  1. - Enter display group

Indicated on VAS 5051:

Fig 2: Function Display VAS 5051 - Generating Readiness Code, Diagnosis Of Oxygen Sensor Aging After Catalytic Converter (4 Of 4)
G03613383Courtesy of AUDI OF AMERICA, INC.
DISPLAY GROUP 044: OXYGEN SENSOR AGING AFTER CATALYTIC CONVERTER (BANK 2)

  Display zones
1 2 3 4
Display group 044: Oxygen sensor aging after catalytic converter (bank 2) 
Display  xxx rpm xxx °C x.xxx V Test ON 
Significance  Engine speed Exhaust gas temperature Voltage of oxygen sensor downstream of catalytic converter, bank 2 Diagnosis status
Operating range  min.: 550 rpm
max.: 6700 rpm
70...850 °C 0.0...1.0 V Test OFF
Test ON
B2-S2 OK
B2-S2 not OK
Specification  700...790 rpm 200...300 °C 0.000...1.000 V B2-S2 OK
Note        If "B2-S2 not OK" is displayed: Interrogate fault memory, see  FAULT MEMORY, INTERROGATING AND ERASING  

If specification "B2 -P2 OK" is obtained in display zone 4: