Work step 6: Diagnostic of oxygen sensor heater

WARNING: This page is about a different car, the 2004 Audi A6, 2003 Audi A6, 2002 Audi A6, 2001 Audi A6, and 2000 Audi A6. However, it is still accessible from the selected car via links, so may be relevant.

When indicated on display

Fig 1: VAG 1551 Scan Tool Display - Work Step 6, Diagnostic Of Oxygen Sensor Heater (1 Of 2)
G03614088Courtesy of AUDI OF AMERICA, INC.

When indicated on display

Fig 2: VAG 1551 Scan Tool Display - Work Step 6, Diagnostic Of Oxygen Sensor Heater (2 Of 2)
G03614089Courtesy of AUDI OF AMERICA, INC.
NOTE: Increasing engine speed accelerates the obtaining of specified values.
DISPLAY GROUP 041: DISPLAY GROUP 041: OXYGEN SENSOR HEATER, BANK 1 AT IDLE

  Display fields
1 2 3 4
Display group 041: Oxygen sensor heater, Bank 1 at idle 
Display  xxx kOhm  Heater before TWC ON  xxx kOhm  Heater after TWC 
ON 
Indicated  Bank 1, Sensor 1 internal resistance of sensor before TWC  Condition of heater  Bank 1, Sensor 2 internal resistance of sensor after TWC  Condition of heater 
Work range    Heater before TWC 
ON 
Heater before TWC 
OFF 
  Heater after TWC 
ON 
Heater after TWC 
OFF 
Specified Value  0 to 0.9 kOhm  Heater before TWC 
ON 
0...0.9 kOhm  Heater after TWC 
ON 
NOTE  NOTE  : See note belowDISPLAY GROUP 042 DIAGNOSING OXYGEN SENSOR HEATER .   NOTE  : See note belowDISPLAY GROUP 042 DIAGNOSING OXYGEN SENSOR HEATER .  
DISPLAY GROUP 042: OXYGEN SENSOR HEATER, BANK 2 AT IDLE

  Display fields
1 2 3 4
Display group 042: Oxygen sensor heater, Bank 2 at idle 
Display  xxx kOhm  Heater before TWC 
ON 
xxx kOhm  Heater after TWC 
ON 
Indicated  Bank 2, Sensor 1 internal resistance of sensor before TWC  Conditions of heater  Bank 2, Sensor 2 internal resistance of sensor after TWC  Condition of heater 
Work range    Heater before TWC 
ON 
Heater before TWC 
OFF 
  Heater after TWC 
ON 
Heater after TWC 
OFF 
Specified Value  0 to 0.9 kOhm  Heater before TWC 
ON 
0 to 0.9 kOhm  Heater after TWC ON 
NOTE  See note below    See note below   

Important note for display groups 41 and 42: Display fields 1 and 3: