Read measuring value block: display group 3

NOTE:
  • The On Board Diagnostic (OBD) is terminated by ABS control module (w/EDL) -J104- if road speed exceeds 19 km/h.
  • If the Torque reduction value is subtracted from the Engine torque value, the result is Engine torque - actual (referred to as MMI)
Fig 1: Read Measuring Value Block Chart (Display Group 3)
G02732570Courtesy of AUDI OF AMERICA, INC.
NOTE: The display group numbers can be selected in sequence by pressing buttons -1- and -3- ((VAG 1551 scan tool) or buttons uparrow and downarrow ((VAG 1552 scan tool) or by pressing" uparrow "and" downarrow" on the screen of VAS 5051 vehicle diagnostic, testing and information system.

Indicated on display

Fig 2: VAG 1551 Scan Tool Display - Enter Display Group Number XXX
G02732571Courtesy of AUDI OF AMERICA, INC.
NOTE: For Read measuring value block: display group 4
  • On control modules with Part No. 4D0 907 389 (without index letter), display group No. 4 is vacant, and cannot be selected by pressing buttons -1- and -3- on VAG 1551 scan tool or buttons uparrow and downarrow on VAG 1552 scan tool.
  • If you try to select Display Group No. 4, the display will show:

Indicated on display

Fig 3: VAG 1551 Scan Tool Display - Function Unknown Or Not Carried Out At Moment
G02732572Courtesy of AUDI OF AMERICA, INC.
Fig 4: VAG 1551 Scan Tool Display - Select Function XX
G02732573Courtesy of AUDI OF AMERICA, INC.

Indicated on display