Test sequence
WARNING: This page is about a different car, the 2003 Audi S6 and 2002 Audi S6. However, it is still accessible from the selected car via links, so may be relevant.
- Connect vehicle diagnostic, testing and information system VAS 5051 or V.A.G 1551 Scan Tool and select engine electronics control unit with "Address word" 01. See VEHICLE DIAGNOSTIC, TESTING AND INFORMATION SYSTEM VAS 5051, CONNECTING AND SELECTING ENGINE CONTROL MODULE or V.A.G 1551 SCAN TOOL, CONNECTING AND SELECTING ENGINE CONTROL MODULE . For this purpose, the ignition must be switched on.
Indicated on display
- Press keys 0 and 8 for function "Read measured value block" and confirm entry with Q key.
Indicated on display
- Press keys 0,8 and 6 for "display group number 86" and confirm entry by pressing Q key.
Display readout:
- Check readiness code in display zone 1
- Specified value: 0 0 0 0 0 0 0 0
DISPLAY GROUP 086: READINESS CODE
| Display zones | ||||
|---|---|---|---|---|
| 1 | 2 | 3 | 4 | |
| Display group 086: Readiness code | ||||
| Display | 0 0 0 0 0 0 0 0 | X X X X X X X X | X X X X X X X | X X X X X X X X X |
| Display | Ready bits | Cycle flags | Cycle flags | Cycle flags |
| Completed tests | Individual tests performed | Individual tests performed | Individual tests performed | |
| Range | 1 = not completed | 1 = not completed | 1 = not completed | 1 = not completed |
| 0 = completed | 0 = completed | 0 = completed | 0 = completed | |
| Specified value | 0 0 0 0 0 0 0 0 | X X X X X X X | X X X X X X X | X X X X X X X X X X |
| Note: | Meaning of readiness code on the next pages | |||
Note on display zone 1:
This display shows which diagnosis was checked since the last erasing of the DTC memory or use of the new control module. After erasing the DTC memory all checkable values are set to 1. After test OK the values are set to 0 .
Note on display zones 2, 3 and 4:
This display shows which diagnosis was started since the last engine start. When engine is switched off the conditions of the diagnosis are set to 1. After diagnosis has been performed the checkable values are set to 0 .
NOTE:
The readiness code is only generated when all the display positions are 0
If the specified value in display zone 1: "0 0 0 0 0 0 0 0" is achieved:
- Press -->key.
Display function selection):
- For control check DTC memory. See DIAGNOSTIC TROUBLE CODE (DTC) MEMORY, CHECKING AND ERASING . (No DTC must be stored.)
If specified value is not attained:
- Generate readiness code. See READINESS CODE, GENERATING .