LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2001 >> S4 Quattro, Automatic >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panels >> Self-Diagnostic System >> Function Mode 10: Adaptation >> Channel 42

Channel 42

NOTE: This function is used to specify a minimal mile performance for service display.
  1. When ADAPTATION INPUT CHANNEL NUMBER XX is displayed, press 4 and 2 keys (42), then press "Q" to confirm input. CHANNEL 42 ADAPTATION 8 MIN-VALUE OIL IN 1000 MILES <-1 3-> will be displayed (8 indicates 8000 miles). Press right arrow key.
  2. CHANNEL 42 ADAPTATION 8 INPUT ADAPTATION VALUE XXXXX will be displayed. Specification is 8000 miles. Enter 00008, then press "Q" to confirm input. CHANNEL 42 ADAPTATION 8 MIN-VALUE OIL IN 1000 MILES <-1 3-> will be displayed. Press "Q" to confirm input.
  3. CHANNEL 42 ADAPTATION 8 STORE CHANGED VALUE will be displayed. Press "Q" to confirm input. CHANNEL 42 ADAPTATION 8 CHANGED VALUE IS STORED will be displayed. Press right arrow key to complete adaptation of minimum mileage.