LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2001 >> S4 Quattro, Automatic >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panels >> Self-Diagnostic System >> Function Mode 10: Adaptation >> Channel 35

Channel 35

NOTE: This function is used to adapt engine speed threshold for oil pressure warning.
  1. When ADAPTATION INPUT CHANNEL NUMBER XX is displayed, press 3 and 5 keys (35), then press "Q" to confirm input. CHANNEL 35 ADAPTATION 0 <-1 3-> will be displayed (0 is factory setting - oil pressure warning is activated if oil pressure decreases to less than 17.4 psi (1.2 bar) at 1500 RPM).
  2. Press right arrow key. CHANNEL 35 ADAPTATION 0 INPUT ADAPTATION VALUE XXXXX will be displayed. Input desired adaptation value range from factory setting of 00000 to custom settings of 00250-01000 in 250 RPM increments. For example, enter 00250. Press "Q" to confirm input. CHANNEL 35 ADAPTATION 250 <-1 3-> will be displayed.
  3. Press "Q" to confirm input. CHANNEL 35 ADAPTATION 250 STORE CHANGED VALUE will be displayed. Press "Q" to confirm input. CHANNEL 35 ADAPTATION 250 CHANGED VALUE IS STORED will be displayed. Press right arrow key to complete adaptation of engine speed threshold.