LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2001 >> S4 Quattro, Automatic >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Self-Diagnostic System >> Function Mode 10: Adaptation >> Channel 46

Channel 46

  1. When ADAPTATION INPUT CHANNEL NUMBER XX is displayed, press 4 and 6 keys (46), then press "Q" to confirm input. CHANNEL 46 ADAPTATION 300 CONSUMPTION AMOUNT IN 1 LITER <-1 3-> will be displayed (300 indicates a value for SRI calculated form various engine data and mileage performance). Press right arrow key.
  2. CHANNEL 46 ADAPTATION 300 INPUT ADAPTATION VALUE XXXXX will be displayed. Specification is 300. Enter 00300, then press "Q" to confirm input. CHANNEL 46 ADAPTATION 300 CONSUMPTION AMOUNT IN 1 LITER <-1 3-> will be displayed. Press "Q" to confirm input.
  3. CHANNEL 46 ADAPTATION 300 STORE CHANGED VALUE will be displayed. Press "Q" to confirm input. CHANNEL 46 ADAPTATION 300 CHANGED VALUE IS STORED will be displayed. Press right arrow key to complete adaptation of total consumption quantity.