HID headlights, adjusting

Special tools, testers and auxiliary items needed 

NOTE:
  • On vehicles with HID headlights, always check, erase and then perform basic setting of fault memory before manually adjusting adjuster screws.
  • Adjust headlights using detailed aiming procedure and specifications

Refer to 01 MAINTENANCE

Preparation 

Fig 1: Connecting VAS 5051 Tester To DLC
GW00015561Courtesy of VOLKSWAGEN UNITED STATES, INC.

Basic setting, initiating 

Fig 2: Diagnostic System VAS 5051: Display -- Basic Setting
GW00006284Courtesy of VOLKSWAGEN UNITED STATES, INC.

Indicated on VAS 5051/5052:

Fig 3: Diagnostic System VAS 5051: Display - Display Group And Key Pad
GW00006285Courtesy of VOLKSWAGEN UNITED STATES, INC.

Indicated on VAS 5051/5052:

1 - Enter display group

Fig 4: Diagnostic System VAS 5051: Display - Basic Setting, Display Group 1 And Wait
GW00017063Courtesy of VOLKSWAGEN UNITED STATES, INC.

Indicated on VAS 5051:

1 - Basic setting

2 - Display group 1

3 - Wait

3 - Headlight adjustment

NOTE: Basic setting 1 deactivates control mode and "Headlights not adjusted" is entered in fault memory.

Adjusting 

Fig 5: Adjustment Screws On Left Headlight
GW00017056Courtesy of VOLKSWAGEN UNITED STATES, INC.

Adjustment screws on left headlight shown. Arrangement on right headlight is mirror image.

1 - Not applicable

2 - Height adjustment screw

3 - Lateral adjustment screw

Refer to 01 MAINTENANCE

Fig 6: Diagnostic System VAS 5051: Display - Basic Setting, Display Group 1 And Wait
GW00017063Courtesy of VOLKSWAGEN UNITED STATES, INC.

Indicated on VAS 5051:

1 - Basic setting

2 - Display group 2

3 - Control position learned

NOTE: Entry in fault memory ("Headlights not adjusted") is erased and control mode re-activated.