Total consumption, adaptation
| Rapid data transfer HELP Select function XX |
Indicated on display:
- Press buttons -1- and -0- and confirm input with Q button.
| Rapid data transfer Q 10 - Adaptation |
Indicated on display:
- Press-Q- button to confirm input.
| Adaptation Enter channel no. XX |
Indicated on display:
- Press buttons -4- and -6- to access "channel 46".
- Press-Q- button to confirm input.
NOTE:
- Displayed value must be adopted on instrument cluster replacement.
- The value indicated does not correspond to the actual consumption but rather to a calculated, averaged value for the service interval indicator based on various distance and engine data.
| Channel 46 Adaptation 300 → Consumption quantity in 1 liter < -1 3- > |
Indicated on display:
- Press → button.
| Channel 46 Adaptation 300 Enter adaptation value XXXXX |
Indicated on display:
- Enter displayed adaptation value via scan tool button pad, filling in initial spaces with "0".
Required value: 300 l
Entry via keypad: 00300
| Channel 46 Adaptation 300 Q Enter adaptation value 00300 |
Indicated on display (example only):
- Press-Q- button to confirm input.
| Channel 46 Adaptation 300 Q Consumption quantity in 1 liter < -1 3- > |
Indicated on display:
- Press-Q- button to confirm input.
| Channel 46 Adaptation 300 Q Store changed value? |
Indicated on display:
- Press-Q- button to confirm input.
| Channel 46 Adaptation 300 → Changed value is stored |
Indicated on display:
- Press → button to terminate adaptation of total consumption.