LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 2000 >> TT Base, 1.8 S >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Electrical Equipment >> 01 On Board Diagnostic (OBD) >> Instrument cluster through m.y. 2000 - VIN 8N_Y040001 and/or software versions from D26 & D03, On Board Diagnostic (OBD) >> Adaptation (function 10) >> SID: time remaining until next Inspection Service (adaptation after replacing instrument cluster)

SID: time remaining until next Inspection Service (adaptation after replacing instrument cluster)

This function is used after replacing the instrument cluster to enter the time remaining (in days) before the next Inspection Service is due.

Rapid data transfer HELP
Select function XX

Indicated on display:

Adaptation
Enter channel number XX

Indicated on display:

The time (in days) remaining before the next Inspection Service is due must be transferred from the old instrument cluster (e.g. 110 days = adaptation value 110).

NOTE:
  • The number can be entered in steps of 1 day; the readout on the display will also be in steps of 1 day.
  • The entered value is counted upward from 0 to 365 days.
  • Input values when replacing instrument cluster. Refer to Replacement instrument cluster input values, adapting  .
  • When using the button pad on the scan tool, the number must be entered directly.
  • If an incorrect value is entered the adaptation function will be terminated and must be re-started.
Channel 41 Adaptation 0
Enter adaptation value XXXXX

Indicated on display:

Example:

Channel 41 Adaptation 0 Q
Enter adaptation value 00110

Indicated on display (example only):

Channel 41 Adaptation 110 Q
< - 1 3- >

Indicated on display:

Channel 41 Adaptation 110 Q
Store changed value?

Indicated on display:

Channel 41 Adaptation 110 →
Changed value is stored

Indicated on display: