Work step 6: Diagnostic of oxygen sensor heater
WARNING: This page is about a different car, the 2004 Audi A6, 2003 Audi A6, 2002 Audi A6, 2001 Audi A6, and 2000 Audi A6. However, it is still accessible from the selected car via links, so may be relevant.
When indicated on display
- Press buttons -0-,-4-, and -1- to select "display group number 041" and confirm with -Q- button.
When indicated on display
- Check specified value in display field 1 and 3:
NOTE:
Increasing engine speed accelerates the obtaining of specified values.
DISPLAY GROUP 041: DISPLAY GROUP 041: OXYGEN SENSOR HEATER, BANK 1 AT IDLE
| Display fields | ||||
|---|---|---|---|---|
| 1 | 2 | 3 | 4 | |
| Display group 041: Oxygen sensor heater, Bank 1 at idle | ||||
| Display | xxx kOhm | Heater before TWC ON | xxx kOhm | Heater after TWC ON |
| Indicated | Bank 1, Sensor 1 internal resistance of sensor before TWC | Condition of heater | Bank 1, Sensor 2 internal resistance of sensor after TWC | Condition of heater |
| Work range | Heater before TWC ON Heater before TWC OFF |
Heater after TWC ON Heater after TWC OFF |
||
| Specified Value | 0 to 0.9 kOhm | Heater before TWC ON |
0...0.9 kOhm | Heater after TWC ON |
| NOTE | NOTE : See note belowDISPLAY GROUP 042 DIAGNOSING OXYGEN SENSOR HEATER . | NOTE : See note belowDISPLAY GROUP 042 DIAGNOSING OXYGEN SENSOR HEATER . | ||
- Press -C- button.
- Press buttons -0-, -4-, and -2- to select "display group number 042" and confirm input with -Q- button.
DISPLAY GROUP 042: OXYGEN SENSOR HEATER, BANK 2 AT IDLE
| Display fields | ||||
|---|---|---|---|---|
| 1 | 2 | 3 | 4 | |
| Display group 042: Oxygen sensor heater, Bank 2 at idle | ||||
| Display | xxx kOhm | Heater before TWC ON |
xxx kOhm | Heater after TWC ON |
| Indicated | Bank 2, Sensor 1 internal resistance of sensor before TWC | Conditions of heater | Bank 2, Sensor 2 internal resistance of sensor after TWC | Condition of heater |
| Work range | Heater before TWC ON Heater before TWC OFF |
Heater after TWC ON Heater after TWC OFF |
||
| Specified Value | 0 to 0.9 kOhm | Heater before TWC ON |
0 to 0.9 kOhm | Heater after TWC ON |
| NOTE | See note below | See note below | ||
Important note for display groups 41 and 42: Display fields 1 and 3:
- Display fields 1 and 3 will not indicate any value if the operating temperature of the oxygen sensors is not reached, that means both fields are empty. (Increase Engine Speed to reach specified value).
- After the operating temperature is reached, the display fields 1 and 3 must display a value of less than 0,9 kOhm
- Only proceed with test after value of less than 0,9 kOhm is displayed with in display fields 1 and 3.
- Press -C- button.