Adaptation of fuel consumption display
Indicated on display
Fig 1: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (1 Of 12)
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Fig 2: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (2 Of 12)
- Press -Q- button to confirm input.
Indicated on display
Fig 3: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (3 Of 12)
- Press buttons -0- and -3-.
- Press -Q- button to confirm input.
NOTE:
- Adaptation only for vehicles with on board computer.
- Value entered must be between 85% and 115%.
- Value must be entered in steps of 5%.
- If the value "100" was changed due to a customer complaint, the changed value must be transferred when replacing instrument cluster.
Indicated on display
Fig 4: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (4 Of 12)
- Press --> button.
NOTE:
Correction of fuel consumption display is only possible via direct input.
Indicated on display
Fig 5: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (5 Of 12)
- Input desired correction value using scan tool keypad, filling initial positions with "0".
Example:
Desired input value: 90%
Keypad input: 00090
Indicated on display
Fig 6: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (6 Of 12)
- Press -Q- button to confirm input.
Indicated on display
Fig 7: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (7 Of 12)
- Press -Q- button to confirm input.
Indicated on display
Fig 8: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (8 Of 12)
- Press -Q- button to confirm input.
Indicated on display
Fig 9: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (9 Of 12)
- Conclude adaptation of the fuel consumption display by pressing the --> button.
Indicated on display
Fig 10: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (10 Of 12)
- Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Fig 11: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (11 Of 12)
- Press -Q- button to confirm input.
NOTE:
If input is incorrect, tester switches to function mode.
Indicated on display
Fig 12: VAG 1551 Scan Tool Display - Adaptation Of Fuel Consumption, Instrument Cluster With Maintenance Interval Extension (12 Of 12)
- Press --> button.
- Select "Adaptation" function 10 again and select adaptation channel 03.