Test requirements:
- Check fuses according to wiring diagram.
- Always check coding of instrument cluster according to coding table. See CODE TABLE: .
- Connect VAG 1551 Scan Tool (ST). See VAG 1551, VAG 1552 SCAN TOOL (ST), CONNECTING AND SELECTING FUNCTIONS .
- Switch ignition ON.
NOTE:
- If the display remains blank, check voltage supply to VAG Scan Tool (ST) according to wiring diagram.
- Additional operating instructions can be called up with the HELP button.
- The -->button is used to advance through the program sequence.
- A wrong input can be erased with the Cbutton.
- In operating mode 1 "Rapid data transfer" the function 00 "Automatic test sequence" can be performed. The DTC memory of all control modules with OBD capability are checked automatically.
- Switch ignition ON.
- Switch on printer with the print button (indicator lamp in button lights up).
- Press button 1 for "Rapid data transfer" mode.
Indicated on display:
Address word for instrument cluster is 17
- Press buttons 1 and 7.
Indicated on display:
- Press Q button to confirm input.
After approx. 5 sec. indicated on display:
Courtesy of AUDI OF AMERICA, INC.
- 4D0919035H: Part number of the instrument cluster (confirm with Parts Dept.)
- D2-KOMBIINTR: component designation
- D10: software version of the instrument cluster
- Code 00283: code for the instrument cluster
- WSC 06812: dealership number
NOTE: Check code using code table. See CODE TABLE: . - Press -->button.
If one of the messages are displayed, perform troubleshooting.
Courtesy of AUDI OF AMERICA, INC.
Courtesy of AUDI OF AMERICA, INC.
Courtesy of AUDI OF AMERICA, INC.
Indicated on display:
- After pressing the HELP button, a list of possible functions is printed.
- Use the -->button advance through the program sequence.