Indicated on VAS 5051:

Fig 1: Function Display VAS 5051 - Measured Value Block, Reading (1 Of 3)
G03613348Courtesy of AUDI OF AMERICA, INC.

Indicated on VAS 5051:

Fig 2: Function Display VAS 5051 - Measured Value Block, Reading (2 Of 3)
G03613349Courtesy of AUDI OF AMERICA, INC.
  1. - Enter display group

Indicated on VAS 5051:

Fig 3: Function Display VAS 5051 - Measured Value Block, Reading (3 Of 3)
G03613350Courtesy of AUDI OF AMERICA, INC.
DISPLAY GROUP 086: READINESS CODE

  Display zones
1 2 3 4
Display group 086: Readiness code 
Display  0 0 0 0 0 0 0 0  X X X X X X X X X X X X X X X X X X X X X X X X 
Significance  Ready bits 
Completed tests 
Individual tests performed Individual tests performed Individual tests performed
Operating range  1 = Not completed 
0 = Completed 
1 = Not completed
0 = Completed
1 = Not completed
0 = Completed
1 = Not completed
0 = Completed
Specification  0 0 0 0 0 0 0 0  X X X X X X X X X X X X X X X X X X X X X X X X
Note    Explanatory notes on readiness code, see the Note below 

Note on display zone 1: 

Of primary importance is display zone 1. This display shows which system has been checked by the self -diagnosis since the fault memory was last erased or a new control module installed. After erasing the fault memory, all values which can be checked are set to "1"; on successful completion of testing the values are set to "0". 

Fig 4: Readiness Code Diagnostic Chart
G03613351Courtesy of AUDI OF AMERICA, INC.
NOTE: Readiness code is only generated if all positions in display zone 1 are set to "0".

If specification "0 0 0 0 0 0 0 0" is obtained in display zone 1:

If reading does not match specification: