Step 3: Adapting throttle valve control module to engine control module: Condition
WARNING: This page is about a different car, the 2003 Audi RS 6. However, it is still accessible from the selected car via links, so may be relevant.
- Engine stopped, ignition on
Indicated on VAS 5051:
Fig 1: Function Display VAS 5051 - Generating Readiness Code, Adapting Throttle Valve Control Module To Engine Control Module (1 Of 3)
- From list -1- select diagnostic function "04 - Basic setting".
Indicated on VAS 5051:
Fig 2: Function Display VAS 5051 - Generating Readiness Code, Adapting Throttle Valve Control Module To Engine Control Module (2 Of 3)
- - Enter display group
- Use keypad -2- to enter "060" for "Display group number 060" and confirm by touching Q key.
Indicated on VAS 5051:
Fig 3: Function Display VAS 5051 - Generating Readiness Code, Adapting Throttle Valve Control Module To Engine Control Module (3 Of 3)
- Activate basic setting by touching key -A-.
- Check display in zones -3- and -4-.
DISPLAY GROUP 060: ADAPTATION OF THROTTLE VALVE CONTROL MODULE
| Display zones | ||||
|---|---|---|---|---|
| 1 | 2 | 3 | 4 | |
| Display group 060: Adaptation of throttle valve control module | ||||
| Display | xx % | xx % | x | - |
| Significance | Throttle valve angle (angle sender 1) |
Throttle valve angle (angle sender 2) |
Adaptation step counter | Adaptation status |
| Operating range | 0...8 | ADP in progress ADP OK ERROR |
||
| Spec. | 3...93 % | 97...3 % | 8 | ADP OK |
| Note | Adaptation step counter is set to 8 on completion of adaptation (values may be skipped) | If "ERROR" is displayed: Interrogate fault memory, see FAULT MEMORY, INTERROGATING AND ERASING If reading does not match specification: see , ANGLE SENSOR 1 FOR THROTTLE DRIVE -G187- AND ANGLE SENSOR 2 FOR THROTTLE DRIVE -G188-, CHECKING . |
||
Note on display zone 3:
During adaptation, various values appear in display zone 3 as an indication of the corresponding adaptation status. The behavior of the adaptation step counter (display zone 3) during adaptation is not the decisive factor, but rather that the specification "ADP OK" appears in display zone 4 on completion of adaptation.
If specification "ADP OK" is obtained:
- Touch > key.
- Proceed with next step.