Step 10: Checking oxygen sensor heating: Condition

WARNING: This page is about a different car, the 2003 Audi RS 6. However, it is still accessible from the selected car via links, so may be relevant.

Indicated on VAS 5051:

Fig 1: Function Display VAS 5051 - Generating Readiness Code, Checking Oxygen Sensor Heating (1 Of 4)
G03613376Courtesy of AUDI OF AMERICA, INC.
  1. - Enter display group

Indicated on VAS 5051:

Fig 2: Function Display VAS 5051 - Generating Readiness Code, Checking Oxygen Sensor Heating (2 Of 4)
G03613377Courtesy of AUDI OF AMERICA, INC.
NOTE: Specifications can be obtained faster by increasing the engine speed (accelerating).
DISPLAY GROUP 41: OXYGEN SENSOR HEATING BANK 1 AT IDLE

  Display zones
1 2 3 4
Display group 41: Oxygen sensor heating bank 1 at idle 
Display  xxx kohms  Upstream heating ON  xxx kohms  Downstream heating ON 
Significance  Bank 1, sensor 1  Heating status  Bank 1, sensor 2  Heating status 
Operating range    Upstream heating ON 
Upstream heating OFF 
  Downstream heating ON 
Downstream heating OFF 
Specification  Less than 1 kohm  Upstream heating ON  Less than 1 kohm  Downstream heating ON 
Note  For notes, look under  DISPLAY ZONES     For notes, look under  DISPLAY ZONES    
NOTE: Heating of cylinder bank 2 oxygen sensors is then checked.


Indicated on VAS 5051:

Fig 1: Function Display VAS 5051 - Generating Readiness Code, Checking Oxygen Sensor Heating (3 Of 4)
G03613378Courtesy of AUDI OF AMERICA, INC.
  1. - Enter display group

Indicated on VAS 5051:

Fig 2: Function Display VAS 5051 - Generating Readiness Code, Checking Oxygen Sensor Heating (4 Of 4)
G03613379Courtesy of AUDI OF AMERICA, INC.
NOTE: Specifications can be obtained faster by increasing the engine speed (accelerating).
DISPLAY GROUP 42: OXYGEN SENSOR HEATING BANK 2 AT IDLE

  Display zones
1 2 3 4
Display group 42: Oxygen sensor heating bank 2 at idle 
Display  xxx kohms  Upstream heating ON  xxx kohms  Downstream heating ON 
Significance  Bank 2, sensor 1  Heating status  Bank 2, sensor 2  Heating status 
Operating range    Upstream heating ON 
Upstream heating OFF 
  Downstream heating ON 
Downstream heating OFF 
Specification  Less than 1 kohm  Upstream heating ON  Less than 1 kohm  Downstream heating ON 
Note  Refer to note below    Refer to note below   

Important notes on display groups 41 and 42 - display zones 1 and 3: