Fault memory, erasing: Requirements

WARNING: This page is about a different car, the 2003 Audi RS 6. However, it is still accessible from the selected car via links, so may be relevant.

After fault memory interrogation:

Fig 1: Function Display VAS 5051 - Fault Memory, Erasing (1 Of 2)
G03613309Courtesy of AUDI OF AMERICA, INC.

Indicated on VAS 5051:

Indicated on VAS 5051:

Fig 2: Function Display VAS 5051 - Fault Memory, Erasing (2 Of 2)
G03613310Courtesy of AUDI OF AMERICA, INC.
    • No display (prior to erasing),

      or

    • Fault memory erased
    NOTE: If the following message appears in display zone -1-: "Fault memory not yet interrogated", this means that the sequence of operations has not been precisely observed. The fault memory cannot be erased until it has been interrogated.
  1. NOTE: Is function to be implemented? Note: Data will be erased:
    • Touch "OK" key on display -2-.
    • End function "05 - Erasing fault memory" by touching --> key.
    • Interrogate fault memory again on completion of repair work and erase if necessary.
NOTE: This erases faults stored during fault elimination e.g. due to connectors being disconnected.