LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 1997 >> A8 Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 133 (On Board Diagnostic (OBD) - 4.2L V8 (AKB, Aux, AYS)) >> On Board Diagnostics (OBD) >> Motronic system, On Board Diagnostic (OBD) >> Readiness code, generating >> Work step 8: Diagnostic of operational readiness of oxygen sensors behind TWC

Work step 8: Diagnostic of operational readiness of oxygen sensors behind TWC

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2003 Audi S8, 2003 Audi A8, 2002 Audi S8, 2002 Audi A8, and 2001 Audi A8. However, it is still accessible from the selected car via links, so may be relevant.

Indicated on Display

Fig 1: VAG1551 Scan Tool Display - Generating Readiness Code: Diagnostic Of Operational Readiness Of Oxygen Sensors Behind TWC (1 Of 2)
G03621311Courtesy of AUDI OF AMERICA, INC.

Indicated on display

Fig 2: VAG1551 Scan Tool Display - Generating Readiness Code: Diagnostic Of Operational Readiness Of Oxygen Sensors Behind TWC (2 Of 2)
G03621312Courtesy of AUDI OF AMERICA, INC.
DISPLAY GROUP 036: OPERATIONAL READINESS OF OXYGEN SENSORS BEHIND TWC (BANK 1 AND BANK 2)

  Display fields
1 2 3 4
Display group 036: Operational readiness of oxygen sensors behind TWC (Bank 1 and Bank 2) 
Display  x.xxx Volt Test ON  x.xxx Volt Test ON 
Indicated  Voltage of oxygen
sensor behind TWC, bank 1
Diagnostic condition  Voltage of oxygen
sensor behind TWC, bank 2
Diagnostic condition 
Work range  0.000V to 1.000 Volt Test OFF 
Test ON 
B2-S2 OK 
B2-S2 not OK 
0.000V to 1.000Volt Test OFF 
Test ON 
B2-S2 OK 
B2-S2 not OK 
Value  less than 0.4 Volt or
greater than 0.5 Volt
B1-S2 OK  less than 0.4 Volt or
greater than 0.5 Volt
B2-S2 OK 
Note    IF "B1-S2 not OK" is displayed: Check DTC Memory, see DIAGNOSTIC TROUBLE CODE (DTC) MEMORY, CHECKING AND ERASING  .   If "B2-S2 not OK" is displayed: Check DTC memory, see DIAGNOSTIC TROUBLE CODE (DTC) MEMORY, CHECKING AND ERASING  .

If the specified value in display field 2 of "B1-S2 OK" and in display field 4 "B2-S2 OK" is reached: