LEMON Manuals: Even more car manuals for everyone
Home >> Audi >> 1997 >> A8 Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 133 (On Board Diagnostic (OBD) - 4.2L V8 (AKB, Aux, AYS)) >> On Board Diagnostics (OBD) >> Motronic system, On Board Diagnostic (OBD) >> Readiness code, generating >> Work step 10: Diagnostic of oxygen sensor aging behind catalytic converter

Work step 10: Diagnostic of oxygen sensor aging behind catalytic converter

WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2003 Audi S8, 2003 Audi A8, 2002 Audi S8, 2002 Audi A8, and 2001 Audi A8. However, it is still accessible from the selected car via links, so may be relevant.

Indicated on display

Fig 1: VAG1551 Scan Tool Display - Generating Readiness Code: Diagnostic Of Oxygen Sensor Aging Behind Catalytic Converter (1 Of 2)
G03621315Courtesy of AUDI OF AMERICA, INC.

Indicated on display

Fig 2: VAG1551 Scan Tool Display - Generating Readiness Code: Diagnostic Of Oxygen Sensor Aging Behind Catalytic Converter (2 Of 2)
G03621316Courtesy of AUDI OF AMERICA, INC.
DISPLAY GROUP 043: OXYGEN SENSOR AGING OXYGEN SENSOR BEHIND TWC (BANK 1)

  Display fields
1 2 3 4
Display group 043: Oxygen sensor aging oxygen sensor behind TWC (Bank 1) 
Display  xxx/RPM xxx °C x.xxx V Test ON 
Indicated  Engine speed (RPM) Catalyst temperature Voltage of oxygen
sensor behind TWC Bank 1
Diagnostic condition
Work range  0 to 6800/RPM 70 to 850 °C 0.000 to 1.000 Volt Test OFF
Test ON
B1-S2 OK
B1-S2 not OK
Value  650 to 720/RPM approx. 250 °C 0.000 to 1.000 Volt B1-S2 OK
Note        If "B1-S2 not OK" is displayed: Check DTC memory, see DIAGNOSTIC TROUBLE CODE (DTC) MEMORY, CHECKING AND ERASING  .

If specified value of "B1-S2 OK" is reached:

DISPLAY GROUP 044: OXYGEN SENSOR AGING OXYGEN SENSOR BEHIND TWC (BANK 2)

  Display fields
1 2 3 4
Display group 044: Oxygen sensor aging oxygen sensor behind TWC (Bank 2) 
Display  xxxx/RPM xxx °C x.xxx Volt Test ON 
Indicated  Engine speed (RPM) Catalyst temperature Voltage of oxygen
sensor behind TWC Bank 2
Diagnostic condition
Work range  0 to 6800/RPM 70 to 850 °C 0.000 to 1.000 Volt Test OFF
Test ON
B2-S2 OK
B2-S2 not OK
Value  650 to 720/RPM approx. 250 °C 0.000 to 1.000 Volt B2-S2 OK
Note        If "B2-S2 not OK" is displayed: Check DTC memory, see DIAGNOSTIC TROUBLE CODE (DTC) MEMORY, CHECKING AND ERASING  .

If specified value of "B2-S2 OK" is reached: