General Precautions
NOTE:
Some systems store data in memory that is lost when the battery is disconnected. Before disconnecting the battery, refer to Battery Terminal Disconnection and Reconnection
.
Please read the following precautions carefully before servicing the SRS, or the airbags could accidentally deploy and cause damage or injuries.
- Except when doing electrical inspections that requires battery power, always press the engine start/stop button to select the OFF mode, disconnect the negative cable from the battery, then wait at least 3 minutes before starting work.NOTE: The SRS memory is not erased even if the engine start/stop button is pressed to select the OFF mode, or if the battery cables are disconnected from the battery.
- Use replacement parts which are manufactured to the same standards and quality as the original parts. Do not install used SRS parts. Use only new parts when making SRS repairs.
- Carefully inspect any SRS part before you install it. Do not install any part that shows signs of being dropped or improperly handled, such as dents, cracks or deformation.
- Before disconnecting the SRS unit connectors, always disconnect the appropriate SRS parts connectors.
- Use only a digital multimeter to check the system. If it is not a Honda multimeter, make sure its output is 10 mA (0.01 A) or less when switched to the lowest value in the ohmmeter range. A tester with a higher output could cause accidental deployment and possible injury.