LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2022 >> ILX >> Repair and Diagnosis >> External Pages >> Different car >> Section 87 (Engine Control System - Advanced Diagnostics (P0420 - P16E4) (Except Hybrid)) >> Advanced Diagnostics >> DTC P06A8 (PGM-FI System (1.5 L Engine))

DTC P06A8 (PGM-FI System (1.5 L Engine))

WARNING: This page is about a different car, the 2022 Honda Accord, 2021 Honda Accord, 2020 Honda Accord, 2019 Honda Accord, and 2018 Honda Accord. However, it is still accessible from the selected car via links, so may be relevant.

DTC P06A8:  Internal VCC Power Malfunction

General Description 

GHH392058Courtesy of HONDA, U.S.A., INC.
GHH392059Courtesy of HONDA, U.S.A., INC.

Main CPU and sub CPU are built into the powertrain control module (PCM). The main CPU supplies 3.3 V power voltage to the sub CPU. The sub CPU converts (A/D conversion) the supplied power voltage and outputs the A/D converted value to the main CPU via serial communication. The main CPU monitors the PCM internal 5 V power supply by comparing with the received value (comparison power supply voltage (3.3 V)) from the sub CPU. When the 5 V power supply is normal, the comparison power supply voltage (3.3 V) falls within a normal area. If the 5 V power supply malfunctions, the comparison power supply voltage (3.3 V) exceeds the range of normal area. If the comparison power supply voltage is out of permissible range for a set time, the PCM detects a malfunction and stores a DTC.

Monitor Execution, Sequence, Duration, DTC Type 

Execution Continuous
Sequence None
Duration 2.0 seconds or more
DTC Type One drive cycle, MIL on

Enable Conditions 

Condition  
Vehicle ON mode

Malfunction Threshold 

The PCM internal comparison power supply voltage is 3.10 V or less, 3.51 V or more for at least 2.0 seconds.

Possible Cause 

NOTE:  The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

Diagnosis Details 

Conditions for setting the DTC 

When a malfunction is detected, the MIL comes on and a Pending DTC, a Confirmed DTC, and the freeze data are stored in the PCM memory.

Conditions for clearing the DTC 

The MIL is cleared if the malfunction does not return in three consecutive trips in which the diagnostic runs. The MIL, the Pending DTC, the Confirmed DTC, and the freeze data can be cleared with the scan tool Clear command or by disconnecting the 12 volt battery.