Power Supply (+B_BACKUP), GND (SGND), Communication (LIN (METER)) Circuit Inspection
Test Procedure
- Preparation
- Gauge control module connector A (32P) : disconnected
- Audio remote-HFL switch 16P connector: disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected)
Audio remote-HFL switch 16P connector female terminals(Disconnected)
Gauge control module connector A (32P) female terminalsIG Mode Normal Conditions +B_BACKUP circuit inspection ON 12 V battery voltage [ circuit type 1 ] SGND open wire inspection OFF There is less than 1 Ω LIN (METER) open wire inspection OFF There is less than 1 Ω NOTE: Refer to the Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.LIN (METER) shorted to ground inspection OFF Not shorted
- Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.NOTE: If the result is not in the normal condition while in the power supply inspection, refer to the Power Supply Inspection , then specify the failure part.