Power Supply (LRP+), GND (LRP-) Shorted Wire Inspection
NOTE:
Before disconnecting the SRS related connector, do the 12 volt battery terminal disconnection procedure and wait for at least 3 minutes.
Test Procedure
- Preparation
- SRS unit connector B (57P) : disconnected
- Driver's seat belt tensioner 2P connector: disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected)
SRS unit connector B (57P) female terminalsIG Mode Normal Conditions LRP+, LRP- shorted wire to wire inspection OFF There is more than 1 MΩ
- Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.