Power Supply (RCA+), GND (RCA-) Open Wire Inspection
NOTE:
Before disconnecting the SRS related connector, do the 12 volt battery terminal disconnection procedure and wait for at least 3 minutes.
Test Procedure
- Preparation
- SRS unit connector B (57P) : disconnected
- Right side curtain airbag inflator 2P connector: disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected)
SRS unit connector B (57P) female terminals(Disconnected)
Right side curtain airbag inflator 2P connector female terminalsIG Mode Normal Conditions RCA+ open wire inspection OFF There is less than 1 Ω RCA- open wire inspection OFF There is less than 1 Ω
- Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.