Power Supply (LA1+), GND (LA1-), Power Supply (LA2+), GND (LA2-), Power Supply (LKA+), GND (LKA-), Power Supply (RA1+), GND (RA1-), Power Supply (RA2+), GND (RA2-), Power Supply (RA3+), GND (RA3-), Power Supply (RKA+), GND (RKA-), Power Supply (LSA+), GND (LSA-), Power Supply (LCA+), GND (LCA-), Power Supply (RSA+), GND (RSA-), Power Supply (RCA+), GND (RCA-), Power Supply (LRP+), GND (LRP-), Power Supply (RRP+), GND (RRP-), Power Supply (LRPT+), GND (LRPT-), Power Supply (RRPT+), GND (RRPT-) Shorted Wire Inspection
Before disconnecting the SRS related connector, do the 12 volt battery terminal disconnection procedure and wait for at least 3 minutes.
Test Procedure
- Preparation
- SRS unit connector A (43P) : disconnected
- SRS unit connector B (57P) : disconnected
- Cable reel connector B (4P) : disconnected
- Inflator connectors which are assigned to 2B codes listed on HDS: disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected)
SRS unit connector A (43P) female terminals(Disconnected)
SRS unit connector B (57P) female terminalsIG Mode Normal Conditions LA1+, LA2+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, LA2- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, LKA+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, LKA- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RA1+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RA1- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RA2+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RA2- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RA3+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RA3- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RKA+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RKA- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, LSA+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, LSA- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, LCA+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, LCA- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RSA+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RSA- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RCA+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RCA- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, LRP+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, LRP- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RRP+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RRP- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, LRPT+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, LRPT- shorted wire to wire inspection OFF There is more than 1 MΩ LA1+, RRPT+ shorted wire to wire inspection OFF There is more than 1 MΩ LA1-, RRPT- shorted wire to wire inspection OFF There is more than 1 MΩ
- Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.