Communication (F-CAN D_H), Communication (F-CAN D_L) Open Wire Inspection
Test Procedure
- Preparation
- Gauge control module connector A (32P) : disconnected
- CAN gateway 16P connector: disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected)
Gauge control module connector A (32P) female terminals(Disconnected)
CAN gateway 16P connectorfemale terminalsIG Mode Normal Conditions F-CAN D_H open wire inspection OFF There is less than 1 Ω F-CAN D_L open wire inspection OFF There is less than 1 Ω
- Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.