Home >> Acura >> 2021 >> RDX Base >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Gauges - Service, Testing And Troubleshooting >> Troubleshooting >> Gauges Symptom Troubleshooting - Integrated Dynamics System Mode Does Not Change >> Inspection

Gauges Symptom Troubleshooting - Integrated Dynamics System Mode Does Not Change: Inspection

Signal (IDS_LEFT), Signal (IDS_RIGHT), GND (GND) Circuit Inspection 

Test Procedure 

           
      (Disconnected)Gauge control module connector A (32P) female terminals (Disconnected)Integrated dynamics system switch 12P connectorfemale terminals  
    IG Mode
GHH334097Courtesy of HONDA, U.S.A., INC.

GHH334098Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  IDS_LEFT open wire inspection  OFF There is less than 1 Ohm 
  IDS_RIGHT open wire inspection  OFF There is less than 1 Ohm 
  GND open wire inspection  OFF   There is less than 1 Ohm 
 
NOTE: Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  IDS_LEFT shorted to ground inspection  OFF   Not shorted 
  IDS_RIGHT shorted to ground inspection  OFF   Not shorted 
   

Results 

Integrated Dynamics System Switch Inspection 

NOTE: Since there is no direct method to test the inspection item, troubleshooting is performed using a known-good component.

Test Procedure 

Results 

Gauge Control Module Inspection 

Test Procedure 

Results