Parking And Back-Up Sensor Control Unit Connector For Inputs And Outputs (2015-17)
| Terminal number | Terminal name | Description | Signal |
|---|---|---|---|
| 1 | IG1 METER | IG1 power source | With vehicle in ON mode: about battery voltage |
| 2 | BOF SIDE R | BOF SIDE R signal | - - - |
| 3 | SOF SIDE R | SOF SIDE R signal | - - - |
| 4 | Not used | - - - | - - - |
| 5 | Not used | - - - | - - - |
| 6 | SOF SIDE L | SOF SIDE L signal | - - - |
| 7 | Not used | - - - | - - - |
| 8 | Not used | - - - | - - - |
| 9 | GND | Ground for parking and back-up sensor control unit | Less than 0.2 V at all times |
| 10 | B-CAN_L | Communication line | - - - |
| 11 | E1 SIDE R | E1 SIDE R signal | - - - |
| 12 | GND | Ground for parking and back-up sensor control unit | - - - |
| 13 | C/SNSR SW | Detects parking and back-up sensor switch signal | With vehicle in ON mode and parking and back-up sensor switch ON: about battery voltage With parking and back-up sensor switch OFF: less than 0.2 V |
| 14 | BOR SIDE L | BOR SIDE L signal | - - - |
| 15 | SOR SIDE R | SOR SIDE R signal | - - - |
| 16 | SOR CTR R | SOR CTR R signal | - - - |
| 17 | SOR CTR L | SOR CTR L signal | - - - |
| 18 | SOR SIDE L | SOR SIDE L signal | - - - |
| 19 | Not used | - - - | - - - |
| 20 | Not used | - - - | - - - |
| 21 | Not used | - - - | - - - |
| 22 | B-CAN_H | Communication line | - - - |
| 23 | E2 SIDE L | E2 SIDE L signal | - - - |
| 24 | C/SNSR IND | Outputs parking and back-up sensor switch indicator signal | Parking and back-up sensor switch indicator OFF: about battery voltage Parking and back-up sensor switch indicator ON: less than 0.2 V |