LEMON Manuals: Even more car manuals for everyone
Home >> Acura >> 2020 >> TLX SH-AWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Gauge Control System - Diagnostics >> DTC Troubleshooting >> DTC U0151: Gauge Control Module Lost Communication With SRS Unit (V6, Gauge Control Module without CAN gateway)

DTC U0151: Gauge Control Module Lost Communication With SRS Unit (V6, Gauge Control Module without CAN gateway)

DTC Description DTC
U0151 Gauge Control Module Lost Communication With SRS Unit  

DTC (Gauge Control Module)

NOTE: 

  1. Problem verification

    -1. Clear the DTCs with the HDS.

    - 2. Turn the vehicle to the OFF (LOCK) mode and then the ON mode.

    - 3. Wait for at least 6 seconds.

    - 4. Check for DTCs with the HDS.

    DTC Description DTC
    U0151 Gauge control module lost communication with SRS unit  

    Is DTC U0151 indicated?

    YES 

    Go to step 2.

    NO 

    Intermittent failure, the system is OK at this time. Check for loose or poor connections.

  2. Open wire check (F-CAN A lines)

    -1. Disconnect the following connector.

    SRS unit connector A (39P)

    - 2. Connect terminals A and B with a jumper wire.

    Terminal A SRS unit connector A (39P) No. 20 - Refer to: SRS Unit Connector For Inputs And Outputs (2015-17) or SRS Unit Connector for Inputs and Outputs (2018-19)
    Terminal B SRS unit connector A (39P) No. 21 - Refer to: SRS Unit Connector For Inputs And Outputs (2015-17) or SRS Unit Connector for Inputs and Outputs (2018-19)

    - 3. Disconnect the following connector.

    Gauge control module 32P connector

    - 4. Check for continuity between test points 1 and 2 respectively.

    Test condition Vehicle OFF (LOCK) mode

    SRS unit connector A (39P): disconnected

    Gauge control module 32P connector: disconnected

    Test point 1 Gauge control module 32P connector No. 27 - Refer to: Gauge Control Module Input Test (2015-17), or Gauge Control Module Input Test (2018-19)
    Test point 2 Gauge control module 32P connector No. 28 - Refer to: Gauge Control Module Input Test (2015-17), or Gauge Control Module Input Test (2018-19)

    Is there continuity?

    YES 

    The F-CAN A wires are OK. Replace the gauge control module .

    NO 

    An open or poor connection in the F-CAN A wires between the SRS unit and the gauge control module.